| Magnetically coupled
centrifugal pumps of building group
1 are non-self-priming
centrifugal pumps with volute casing. They operate in
horizontal position and are built in monobloc design.
A magnetic coupling connects the pump to the electromotor
and transmits the power of the motor to the impeller.
|
 |
Constructional design |
Housing, impeller, impeller magnet coating and rear casing are made of either glass-fibre reinforced PP plastic or PVDF or stainless steel. Sleeve bearings, starting ring and centering shaft are made of 99.7% pure oxide ceramic. O-ring sealing of the housing is made of FPM or EPDM or FEP (optionally available).
|
For aggressive and neutral liquids |
|
For short-term and continuous operation |
|
|
 |
|
|
| |
Made of |
PP, PVDF, stainless steel |
| |
Delivery rate |
up to 30 l/min |
| |
Delivery head |
up to 4.9m wc |
| |
Density * |
up to 1.85 g/cm³
|
| |
Motor |
400V three-phase motor or 230V single-phase ac capacitor start-and-run motor, 60 watts, 50 Hz, insulation class F, protection class IP 55 motor speed 2,850min-1 - Other voltages and frequencies are available on request. - |
| |
Weight approx. |
2.7 to 3.4kg |
| |
Fluid temperature range |
PP -20° to +80°C |
PVDF -20° to +95°C |
steel -20° to +95°C |
| |
Pressure range ** |
PP up to 1.0 bar |
PVDF up to 2.0 bar |
steel up to 8.0 bar |
| |
Position of terminal box |
standard position is on top |
| |
Position of discharge port |
vertical position is standard differing positions of 12x30° are possible |
| |
Ports acc. to German DIN 8063 standard |
suction port: d25/DN20 - G 1¼ discharge port: d20/DN16 - G 1 |
| |
Accessories (optional) |
pilotherm for 230V ac ON/OFF switch with cable 2.5m long and plug for 230V ac motor circuit-breaker for 400V three-phase current connection cable 5m long with CEE plug flexible hoses non-return valve three-piece hose connection (incl. hose nipple, spigot nut and O-ring) |
| * |
To deliver liquids with a higher relative density, we also offer all our pumps with smaller impeller diameters which, however, reduce delivery rates and heads of the pumps. If in doubt, please consult us. |
| ** |
Maximum system pressure depends on the temperature of the fluid delivered. |
| |
|
Get more information
|
|
| Files
available in |
German |
English |
|
| RM
pump brochure |
|
|
254 K |
| Operating
instructions |
|
|
152 K |
|
|
|
 |
 |
|
|
|
|