| Magnetically coupled
centrifugal pumps of building group
2 are non-self-priming
centrifugal pumps with volute casing. They operate in
horizontal position and are built in monobloc design.
A magnetic coupling connects the pump to the electromotor
and transmits the power of the motor to the impeller.
|
 |
Constructional design |
Housing, impeller, impeller magnet coating and rear casing can be made of either glass-fibre reinforced PP plastic or PVDF. Sleeve bearings, starting ring and centering shaft are made of 99.7% pure oxide ceramic. O-ring sealing of the housing is made of FPM or EPDM or FEP (optionally available).
|
For aggressive and neutral liquids |
|
For short-term and continuous operation |
 |
With non-ventilated motor
so that it is insensitive to vapour. |
|
|
 |
|
|
| |
Made of |
PP, PVDF |
| |
Delivery rate |
up to 118 l/min |
| |
Delivery head |
up to 9.5m wc |
| |
Density * |
up to 2.5 g/cm³
|
| |
Motor |
230/400V three-phase motor or 230V single-phase ac capacitor start-and-run motor,
90 to 370 watts, 50 Hz, insulation class F, protection class
IP 55
motor speed 2,850min-1 - Other voltages and frequencies are available on request. - |
| |
Weight approx. |
4.0 to 7.5kg |
| |
Fluid temperature range |
PP -20° to +80°C |
PVDF -20° to +95°C |
| |
Pressure range ** |
PP up to 2.5 bar |
PVDF up to 3.5 bar |
| |
Position of terminal box |
vertical position is standard positions turned to the right or the left are possible |
| |
Position of discharge port |
vertical position is standard differing positions of 6x60° are possible |
| |
Ports acc. to German DIN 8063 standard |
suction port: d25/DN20 - G1¼ discharge port: d25/DN20 - G1¼ |
| |
Accessories (optional) |
explosion-proof motor (only with 180 and 250 watts capacity) motor circuit-breaker for 230/400V three-phase current connection cable 5m long with CEE-plug pilotherm for 230V ac ON/OFF switch with connection cable 2.5m long and plug for 230V ac flanges flexible hoses non-return valve three-piece hose connection (incl. hose nipple, spigot nut and O-ring) |
| * |
To deliver liquids with a higher relative density, we also offer all our pumps with smaller impeller diameters which, however, reduce delivery rates and heads of the pumps. If in doubt, please consult us. |
| ** |
Maximum system pressure depends on the temperature of the fluid delivered. |
| |
|