RM building group 4.5
 

 

 
Magnetically coupled centrifugal pumps of building group 4.5 are non-self-priming centrifugal pumps with volute casing. They operate in horizontal position and are built in monobloc design. A magnetic coupling connects the pump to the electromotor and transmits the power of the motor to the impeller.

Constructional design
Housing, impeller, impeller magnet coating and rear casing can be made of either glass-fibre reinforced PP plastic or PVDF. Sleeve bearings, starting rings and centering shaft are made of 99.7% pure oxide ceramic. The impeller starting ring is made of PTFE graphite. O-ring sealing of the housing is made of FPM or EPDM or FEP (optionally available).

For aggressive and neutral liquids
For short-term and continuous operation

Pump sizes 10/550 | 18/550 | 23/650 | 27/750 | 30/850
   
  Made of PP, PVDF
  Delivery rate up to 900 l/min
  Delivery head up to 32m wc
  Density * up to 1.8 g/cm³
  Motor 230/400V three-phase motor, 2.2 to 7.5kW,
50 Hz, insulation class F, protection class IP 54
motor speed 2,900min-1
- Other voltages and frequencies are available on request. -
  Weight approx. 28.0 to 57.0kg
  Fluid temperature range PP -20° to +80°C PVDF -20° to +95°C
  Pressure range ** PP up to 5.0 bar PVDF up to 6.0 bar
  Position of terminal box
vertical position is standard
positions turned to the right or the left are possible
  Position of discharge port vertical position is standard
differing positions of 12x30° are possible
  Ports acc. to German DIN 8063 standard suction port:  d63/DN50 - G2¾
discharge port: d50/DN40 - G2¼
  Accessories (optional) explosion-proof motor
three-phase motor with frequency converter
motor circuit-breaker for 230/400V three-phase motor
connection cable 5m long with CEE plug
flanges
flexible hoses
non-return valve
three-piece hose connection (incl. hose nipple, spigot nut and O-ring)

* To deliver liquids with a higher relative density, we also offer all our pumps with smaller impeller diameters which, however, reduce delivery rates and heads of the pumps. If in doubt, please consult us.
** Maximum system pressure depends on the temperature of the fluid delivered.
   